• DocumentCode
    166858
  • Title

    Modeling of the test-fixture / Horizontal Coupling Plane interaction in system-level ESD test setups

  • Author

    Tazzoli, A. ; Malobabic, S. ; Vashchenko, V.

  • Author_Institution
    Maxim Integrated Corp., San Jose, CA, USA
  • fYear
    2014
  • fDate
    7-12 Sept. 2014
  • Firstpage
    1
  • Lastpage
    7
  • Abstract
    Experimental results supported by mixed-mode simulations show how standalone ESD clamps can provide different passing levels from system-level ESD tests due to the variable impedance of the discharge current path with varied test-board size. This can lead to overdesign of the ESD protection clamp if IEC61000-4-2 current amplitudes specifications are considered, or misleading test results.
  • Keywords
    IEC standards; electrostatic discharge; finite element analysis; semiconductor device testing; thyristors; ESD protection clamp; FEM; IEC61000-4-2 current amplitude specifications; SCR; discharge current path; finite element method; horizontal coupling plane interaction; mixed-mode simulations; silicon controlled rectifier; system-level ESD test setups; test fixture; test-board size; Capacitance; Clamps; Discharges (electric); Electrostatic discharges; Impedance; Integrated circuit modeling; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Overstress/Electrostatic Discharge Symposium (EOS/ESD), 2014 36th
  • Conference_Location
    Tucson, AZ
  • ISSN
    0739-5159
  • Type

    conf

  • Filename
    6968867