• DocumentCode
    1669570
  • Title

    Simulation of Hemodynamics in Bypassed Aortic Dissection

  • Author

    Qiao, Aike ; Gu, Zhaoyong ; Meng, Xianlong

  • Author_Institution
    Beijing Univ. of Technol., Beijing
  • fYear
    2008
  • Firstpage
    1851
  • Lastpage
    1854
  • Abstract
    In order to verify the feasibility of bypass graft treatment for DeBakey III aortic dissection, numerical simulation using computational fluid dynamics method was performed to compare the hemodynamics of non-bypassed and bypassed DeBakey III aortic dissection. The numerical results demonstrated that the flow activity and pressure in the false lumen decreased after the implantation of bypass graft, which is profitable for the alleviation of dissection propagation, and the promotion of dissection exclusion. Thus, bypass graft can be an alternative for the surgical therapy of DeBakey III aortic dissection.
  • Keywords
    cardiovascular system; diseases; haemodynamics; physiological models; surgery; DeBakey III aortic dissection; bypassed aortic dissection; computational fluid dynamics; hemodynamics; Blood flow; Blood pressure; Computational fluid dynamics; Computational modeling; Hemodynamics; Mechanical factors; Medical treatment; Numerical simulation; Stress; Surgery;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Bioinformatics and Biomedical Engineering, 2008. ICBBE 2008. The 2nd International Conference on
  • Conference_Location
    Shanghai
  • Print_ISBN
    978-1-4244-1747-6
  • Electronic_ISBN
    978-1-4244-1748-3
  • Type

    conf

  • DOI
    10.1109/ICBBE.2008.792
  • Filename
    4535672