DocumentCode
1671205
Title
Application of Natural Commutation Technique to Center-Tapped HF Link Inverter
Author
Nge, Chee-Lim ; Salam, Z.
Author_Institution
Global Technoloy Dev. Group, Gov. & Enterprise Mobility Solutions
Volume
1
fYear
0
Firstpage
90
Lastpage
94
Abstract
This paper explores the possibility of applying natural commutation technique to center-tapped HF link inverter. Natural commutation technique has been applied to bridge-type HF link inverter to solve the problems of switching loss and voltage surge across transformer secondary. The condition of natural commutation mechanism in HF link inverter is investigated to enable the design of modified switching technique. The theoretical analysis is verified with experimental results
Keywords
bridge circuits; commutation; invertors; power transformers; surges; switching convertors; bridge-type HF link inverter; center-tapped HF link inverter; natural commutation technique; switching loss; transformers; voltage surge; Arm; Commutation; Frequency conversion; Hafnium; Inductance; MOSFETs; Pulse width modulation inverters; Switches; Switching converters; Switching loss; high-frequency link inverter; soft-switching;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics and Drives Systems, 2005. PEDS 2005. International Conference on
Conference_Location
Kuala Lumpur
Print_ISBN
0-7803-9296-5
Type
conf
DOI
10.1109/PEDS.2005.1619666
Filename
1619666
Link To Document