DocumentCode
1675697
Title
Acceleration sensitivity study for commercially available SAW oscillators
Author
McGowan, R. ; Kosinski, J. ; Lindenmuth, R. ; Himmel, J. ; Lukaszek, T.
Author_Institution
ARL Electron. & Power Sources Directorate, Ft. Monmouth, NJ, USA
fYear
1993
Firstpage
381
Abstract
The present study was initially devised to accomplish two objectives. The primary objective was to determine the feasibility of using commercially available SAW (surface acoustic wave) oscillators to meet the stringent acceleration sensitivity requirement of 10/sup -11//g needed for state-of-the-art military applications. The second objective was to establish a performance baseline of acceleration sensitivity since there was very little preexisting data for use by system developers. However, when the acceleration sensitivity data collected for the various oscillators were correlated with the physical attributes of the oscillator circuits and SAW resonators, more general design guidelines could be inferred from the data for the production of vibration insensitive oscillators. The complete data set resulting from the shake table tests is far more comprehensive than the information provided by a manufacturer.<>
Keywords
radiofrequency oscillators; surface acoustic wave devices; SAW oscillators; acceleration sensitivity requirement; design guidelines; military applications; shake table tests; vibration insensitive oscillators; Acceleration; Accelerometers; Frequency; Life estimation; Oscillators; Phase detection; Radar detection; Surface acoustic waves; Testing; Vibration measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Symposium Digest, 1993., IEEE MTT-S International
Conference_Location
Atlanta, GA, USA
ISSN
0149-645X
Print_ISBN
0-7803-1209-0
Type
conf
DOI
10.1109/MWSYM.1993.276798
Filename
276798
Link To Document