    Correction of organ motion in SPECT using reprojection data

  • Author

    Arata, K. ; Pretorius, P.H. ; King, M.A.

  • Author_Institution
    Picker Int., Highland Heights, OH, USA
  • Volume
    3
  • fYear
    1995
  • Firstpage
    1456
  • Abstract
    Organ motion during SPECT acquisition can cause artifacts in the reconstructed slices which may affect the clinical interpretation. A new algorithm is presented which corrects for translational organ motion in SPECT projection data and thus reduces the resulting artifacts. The projection data is first reconstructed and then reprojected to the original angles. These reprojection data provide a template for comparison with the true projection data to estimate motion. An organ of interest is selected interactively using a count threshold on the reconstructed slices. From this, regions of interest are reprojected and used to limit the region of comparison and improve efficiency. Parabolic interpolation is used to interpolate fractional shifts. The algorithm corrects for translational motion in the projection data along both X and Y axes. The algorithm was evaluated using point sources in air with physical motion induced during acquisition and artificially induced motion using Monte Carlo simulated MCAT phantom data. Results show that the FWHM´s and FWTM´s of corrected point source data compare favorably with point source data without motion induced. Polar maps of the MCAT phantom clearly show the improvement after the correction was implemented. Further validation and clinical testing are in progress
  • Keywords
    biomechanics; image reconstruction; interpolation; medical image processing; motion estimation; single photon emission computed tomography; Monte Carlo simulated MCAT phantom data; SPECT acquisition; clinical interpretation; clinical testing; count threshold; fractional shifts interpolation; image artifacts; medical diagnostic imaging; nuclear medicine; organ motion correction; parabolic interpolation; point sources; polar maps; reconstructed slices; reprojection data; Cameras; Heart; Image reconstruction; Imaging phantoms; Interpolation; Monte Carlo methods; Motion detection; Motion estimation; Testing; Thyristors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference Record, 1995., 1995 IEEE
  • Conference_Location
    San Francisco, CA
  • Print_ISBN
    0-7803-3180-X
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1995.500301
  • Filename
    500301