DocumentCode
1693417
Title
Microvascular red blood cell velocity measurement using the image gradient method
Author
Umetani, Jun ; Yuzawa, Chikayoshi ; Okada, Eiji ; Sekizuka, Eiichi ; Oshio, Chikara ; Minamitani, Haruyuki
Author_Institution
Dept. of Electr. Eng., Keio Univ., Kanagawa, Japan
fYear
1989
Firstpage
624
Abstract
An image analysis system is described for the measurement of the blood velocity and the flow profile in microcirculation. It uses a super-high-speed video tape recorder (100 frames/s) and the image gradient method. The measured mean red blood cell velocity of the microvessels (venules having diameters of 15-40 μm) is 0.7-4.0 mm/s and the measured mean flow volume is 0.7-5.0×10-3 mm 3/s. A flow chart of the image processing algorithm and results which show the velocity vectors and temporal change of the red blood cell velocity are given
Keywords
biological techniques and instruments; biorheology; blood; cellular transport and dynamics; velocity measurement; 15 to 40 micron; biological technique; flow profile; haemorheology; image analysis system; image gradient method; image processing algorithm; microvascular red blood cell velocity measurement; super-high-speed video tape recorder; venules; Blood flow; Fluid flow measurement; Gradient methods; High speed optical techniques; Image analysis; Image processing; Microscopy; Pixel; Red blood cells; Velocity measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 1989. Images of the Twenty-First Century., Proceedings of the Annual International Conference of the IEEE Engineering in
Conference_Location
Seattle, WA
Type
conf
DOI
10.1109/IEMBS.1989.95904
Filename
95904