DocumentCode
1693559
Title
High frequency power conversion for varying load conditions
Author
Kern, A. ; Yu, B.-H.
Author_Institution
Dept. of Power Electron. & Electr. Drives, Siegen Univ., Germany
Volume
1
fYear
1995
Firstpage
407
Abstract
Tubular fluorescent lamps used in industrial printing machines are powered by conventional transformers. These configurations have severe disadvantages concerning maintenance, space requirements and energy efficiency. In this paper a system is presented which eliminates these disadvantages and makes it possible to control the luminous flux of the fluorescent lamp over a wide range. The power supply system requires approximately the same space as a standard PC-switching power supply device of about 300 W. The applied concepts will be explained and accompanied by practical results
Keywords
fluorescent lamps; load (electric); power conversion; power supplies to apparatus; printing; energy efficiency; high frequency power conversion; industrial printing machines; load conditions; luminous flux; maintenance; power supply system; space requirements; tubular fluorescent lamps; Control systems; Electrical equipment industry; Electricity supply industry; Energy efficiency; Fluorescent lamps; Frequency conversion; Power conversion; Power supplies; Printing machinery; Transformers;
fLanguage
English
Publisher
ieee
Conference_Titel
Microelectronics, 1995. Proceedings., 1995 20th International Conference on
Conference_Location
Nis
Print_ISBN
0-7803-2786-1
Type
conf
DOI
10.1109/ICMEL.1995.500901
Filename
500901