    Study on method of improvement about Annubar Flowmeter base on numerical simulation

  • Author

    Yang, Kang ; Xie, Dailiang ; Tao, Shan ; Su, Zhongdi ; Zhang, Hongjun ; Zhao, Weiguo

  • Author_Institution
    Coll. of Metrol. Technol. & Eng., China Jiliang Univ., Hangzhou, China
  • fYear
    2010
  • Firstpage
    5385
  • Lastpage
    5389
  • Abstract
    For the difficulties of obtaining the discharge coefficient of the Annubar Flowmeters at large diameters, some attempt were made to improve this meter based on the numerical simulation. Some researches were done on two flowmeters with different blockage ratio under the condition of fully developed fluid by using standard k-ε turbulence model. The measurement characteristics of both flowmeters, such as pressure loss, linearity of discharge coefficient were calculated and compared. The results show that the impact of surface roughness is small. Linearity of discharge coefficient of both flowmeter is agreed with experimental results. The pressure loss of improved flowmeter is smaller than before. The experimental measurement characteristics of improved one are agreed with the simulation. Larger output differential pressure could be obtained.
  • Keywords
    flowmeters; numerical analysis; surface roughness; Annubar flowmeter; discharge coefficient; numerical simulation; pressure loss; surface roughness; Discharges; Education; Electron tubes; Instruments; Linearity; Loss measurement; Numerical simulation; Annubar Flowmeters; discharge coefficient; measurement characteristics; numerical simulation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Intelligent Control and Automation (WCICA), 2010 8th World Congress on
  • Conference_Location
    Jinan
  • Print_ISBN
    978-1-4244-6712-9
  • Type

    conf

  • DOI
    10.1109/WCICA.2010.5554971
  • Filename
    5554971