DocumentCode
1703592
Title
Charged particle detection with PbWO4
Author
Hoek, M. ; Döring, W. ; Hejny, V. ; Löhner, H. ; Metag, V. ; Novotny, R. ; Wörtche, H.
Author_Institution
II Phys. Inst., Giessen Univ., Germany
Volume
1
fYear
2001
Firstpage
555
Abstract
The response of PbWO4 to high energy protons has been investigated in two test experiments at the proton beam facilities COSY and AGOR. The determined energy resolution below 360 MeV of σ/E=0.97%/Eγ12/+3.33% is comparable to the previously deduced photon response. Energy spectra of inelastically scattered protons below 85 MeV are compared to similar distributions obtained for BaF2- and CeF3-detectors, respectively. The comparison to the response of charged pions indicates an strong quenching effect of the scintillation light for hydrogen isotopes.
Keywords
calibration; lead compounds; particle calorimetry; photomultipliers; position sensitive particle detectors; proton detection; solid scintillation detectors; 0 to 360 MeV; AGOR; COSY; PbWO4; charged particle detection; charged pions; deduced photon response; electromagnetic calorimetry; energy resolution; energy spectra; high energy proton detection; hydrogen isotopes; inelastically scattered protons; photomultiplier tubes; proton beam facilities; quenching effect; scintillation light; Cyclotrons; Detectors; Mesons; Optical scattering; Particle scattering; Performance evaluation; Photomultipliers; Plastics; Protons; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2001 IEEE
ISSN
1082-3654
Print_ISBN
0-7803-7324-3
Type
conf
DOI
10.1109/NSSMIC.2001.1008518
Filename
1008518
Link To Document