Title
New control technique for compensation of neutral current harmonics in three-phase four-wire systems
Author
Zadeh, J. Keramati ; Farjah, E.
Author_Institution
Electr. & Comput. Eng. Dept., Shiraz Univ., Shiraz, Iran
fYear
2009
Firstpage
1
Lastpage
6
Abstract
Use of nonlinear loads such as power electronic converters, power supplies used in personal computers and etc is the main cause of harmonics in power distribution systems. Hence, voltage distortion on utility outlets and excessive neutral current on distribution lines have arisen and lead to a number of serious problems in distribution systems. In this paper, a series active filter is proposed to be placed in neutral of a three-phase, four-wire distribution system. This filter interacts with neutral by injecting proper current in order to suppress the excessive current harmonics, this in turn will prevent the overloading of the neutral conUse of Nonlinear loads such as power electronic converters, power supplies used in personal computers and etc is the main cause of harmonics in power distribution systems. Hence, voltage distortion on utility outlets and excessive neutral current on distribution lines have arisen and lead to a number of serious problems in distribution systems. In this paper, a series active filter is proposed to be placed in neutral of a three-phase, four-wire distribution system. This filter interacts with neutral by injecting proper current in order to suppress the excessive current harmonics, this in turn will prevent the overloading of the neutral conductor and the distribution transformer. Detailed analysis of the proposed system will be presented. Also a new control method and the related compensation characteristics of a series active filter connected in the neutral conductor are presented in this paper. This approach has been simulated using MATLAB.ductor and the distribution transformer. Detailed analysis of the proposed system will be presented. Also a new control method and the related compensation characteristics of a series active filter connected in the neutral conductor are presented in this paper. This approach has been simulated using MATLAB.
Keywords
active filters; distribution networks; power harmonic filters; power supply quality; power system control; MATLAB; active filter; control technique; distribution transformer; neutral current harmonic compensation; nonlinear load; power distribution system; three-phase four-wire distribution system; three-phase four-wire systems; voltage distortion; Active filters; Conductors; Control systems; Microcomputers; Power distribution; Power electronics; Power harmonic filters; Power supplies; Power system harmonics; Voltage; Harmonic voltage distortion; neutral conductor; nonlinear loads; series active filter; third harmonic;
fLanguage
English
Publisher
ieee
Conference_Titel
PowerTech, 2009 IEEE Bucharest
Conference_Location
Bucharest
Print_ISBN
978-1-4244-2234-0
Electronic_ISBN
978-1-4244-2235-7
Type
conf
DOI
10.1109/PTC.2009.5281802
Filename
5281802
Link To Document