DocumentCode
1717458
Title
X-ray spot measurement and modulation transfer function for the 12 MeV LIA
Author
Shi Jinshui ; Li Jing ; Li Qing ; Luo Dashi
Author_Institution
Inst. of Fluid Phys., CAEP, Chengdu, China
fYear
1999
Firstpage
320
Abstract
Summary form only given. This paper is intended to present the experimental system measuring the X-ray spot size for the 12 MeV LIA. By means of one-time discharge, the system adopts the sharpness-edge method and big-aperture imaging simultaneously, thereby acquiring the size of the X-ray spot. Further on, by numerical calculation with the pre-designed program, and on the basis of the characteristics of the approximate axial symmetry of the X-ray source and the density distribution of the image, the space distribution of spot intensity is simulated. At the same time, the system can determine the modulation transfer function of the space resolution of the X-ray imaging for the 12 MeV LIA.
Keywords
linear accelerators; optical transfer function; 12 MeV; 12 MeV LIA; X-ray imaging; X-ray source; X-ray spot measurement; X-ray spot size measurement; axial symmetry; big-aperture imaging; density distribution; linear induction accelerator; modulation transfer function; one-time discharge; pre-designed program; sharpness-edge method; space distribution; space resolution; spot intensity; Cathodes; Electron beams; Frequency; High power microwave generation; Microwave devices; Microwave oscillators; Optical imaging; Physics; Transfer functions; X-ray imaging;
fLanguage
English
Publisher
ieee
Conference_Titel
Plasma Science, 1999. ICOPS '99. IEEE Conference Record - Abstracts. 1999 IEEE International Conference on
Conference_Location
Monterey, CA, USA
ISSN
0730-9244
Print_ISBN
0-7803-5224-6
Type
conf
DOI
10.1109/PLASMA.1999.829710
Filename
829710
Link To Document