• DocumentCode
    1717458
  • Title

    X-ray spot measurement and modulation transfer function for the 12 MeV LIA

  • Author

    Shi Jinshui ; Li Jing ; Li Qing ; Luo Dashi

  • Author_Institution
    Inst. of Fluid Phys., CAEP, Chengdu, China
  • fYear
    1999
  • Firstpage
    320
  • Abstract
    Summary form only given. This paper is intended to present the experimental system measuring the X-ray spot size for the 12 MeV LIA. By means of one-time discharge, the system adopts the sharpness-edge method and big-aperture imaging simultaneously, thereby acquiring the size of the X-ray spot. Further on, by numerical calculation with the pre-designed program, and on the basis of the characteristics of the approximate axial symmetry of the X-ray source and the density distribution of the image, the space distribution of spot intensity is simulated. At the same time, the system can determine the modulation transfer function of the space resolution of the X-ray imaging for the 12 MeV LIA.
  • Keywords
    linear accelerators; optical transfer function; 12 MeV; 12 MeV LIA; X-ray imaging; X-ray source; X-ray spot measurement; X-ray spot size measurement; axial symmetry; big-aperture imaging; density distribution; linear induction accelerator; modulation transfer function; one-time discharge; pre-designed program; sharpness-edge method; space distribution; space resolution; spot intensity; Cathodes; Electron beams; Frequency; High power microwave generation; Microwave devices; Microwave oscillators; Optical imaging; Physics; Transfer functions; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science, 1999. ICOPS '99. IEEE Conference Record - Abstracts. 1999 IEEE International Conference on
  • Conference_Location
    Monterey, CA, USA
  • ISSN
    0730-9244
  • Print_ISBN
    0-7803-5224-6
  • Type

    conf

  • DOI
    10.1109/PLASMA.1999.829710
  • Filename
    829710