• DocumentCode
    1732314
  • Title

    Semi-empirical model for helical magnetocumulative generators

  • Author

    Altgilbers, Larry L.

  • Author_Institution
    Adv. Technol. Directorate, U.S. Army Space & Missile Deftnse Command, Huntsville, AL, USA
  • fYear
    2001
  • Firstpage
    230
  • Abstract
    Summary form only given. A semi-empirical model of a helical magnetocumulative generator (MCG) has been developed with a single adjustable variable (called the characteristic time) that describes the time dependent changes in the output current of these generators. A brief description of this model and the characteristic time will be presented. This model has been used to analyze several helical MCGs including the Mark IX, Flexy-I, EF-3, Ranchito, and Jemez generators and it was found that there is relative good agreement between the calculated and experimental data. Due to its simplicity, speed, and the fact that it appears to be independent of the type of helical generator being modeled and the nature of the load, this model can serve as an initial design code.
  • Keywords
    pulse generators; pulsed power supplies; EF-3 generator; Flexy-1 generator; Jemez generator; Mark IX generator; Ranchito generator; characteristic time; helical magnetocumulative generator; output current; semi-empirical model; single adjustable variable; time dependent changes; Character generation; Load modeling; Magnetic analysis; Missiles;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Plasma Science, 2001. IEEE Conference Record - Abstracts
  • Conference_Location
    Las Vegas, NV, USA
  • Print_ISBN
    0-7803-7141-0
  • Type

    conf

  • DOI
    10.1109/PPPS.2001.960839
  • Filename
    960839