• DocumentCode
    1760549
  • Title

    Monte Carlo Bias Field Correction in Endorectal Diffusion Imaging

  • Author

    Lui, Dorothy ; Modhafar, Amen ; Glaister, Jeffrey ; Wong, Alexander ; Haider, M.A.

  • Author_Institution
    Dept. of Syst. Design Eng., Univ. of Waterloo, Waterloo, ON, Canada
  • Volume
    61
  • Issue
    2
  • fYear
    2014
  • fDate
    Feb. 2014
  • Firstpage
    368
  • Lastpage
    380
  • Abstract
    Prostate cancer is one of the leading causes of cancer death in the male population. The detection of prostate cancer using imaging has been challenging until recently. Multiparametric magnetic resonance imaging (MRI) has been shown to allow accurate localization of the cancers and can help direct biopsies to cancer foci, which is required to plan the treatment. The interpretation of MRI, however, requires a high level of expertise and review of large multiparametric datasets. An endorectal receiver coil is often used to improve signal-to-noise ratio and aid in detection of smaller cancer foci. Moreover, computed high b-value diffusion-weighted imaging show improved delineation of tumors but is subject to strong bias fields near the coil. Here, a nonparametric approach to bias field correction for endorectal diffusion imaging via Monte Carlo sampling is introduced. It will be shown that the delineation between the prostate gland and the background and intensity inhomogeneity may be improved using the proposed approach. High b-value generated results also show improved visualization of tumor regions. The results suggest that Monte Carlo bias correction may have potential as a preprocessing tool for endorectal diffusion images for the prostate cancer detection and localization or segmentation.
  • Keywords
    Monte Carlo methods; biodiffusion; biological organs; biomedical MRI; cancer; edge detection; feature extraction; image segmentation; medical image processing; sampling methods; tumours; MRI; Monte Carlo bias field correction; Monte Carlo sampling; accurate cancer localization; biopsies; endorectal diffusion imaging; endorectal receiver coil; high b-value diffusion-weighted imaging; intensity inhomogeneity improvement; multiparametric magnetic resonance imaging; preprocessing tool; prostate cancer detection; prostate cancer localization; prostate cancer segmentation; prostate gland- background delineation; signal-to-noise ratio improvement; small cancer foci detection; treatment planning; tumor region visualization; tumors delineation improvement; Coils; Magnetic resonance imaging; Nonhomogeneous media; Phantoms; Principal component analysis; Signal to noise ratio; Bias correction; endorectal diffusion imaging; prostate cancer (PCa);
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2013.2279635
  • Filename
    6585752