• DocumentCode
    1761630
  • Title

    An Implantable Pressure Sensing System With Electromechanical Interrogation Scheme

  • Author

    Kim, A-Rong ; Powell, Charles R. ; Ziaie, Babak

  • Author_Institution
    Sch. of Electr. & Comput. Eng., Purdue Univ., West Lafayette, IN, USA
  • Volume
    61
  • Issue
    7
  • fYear
    2014
  • fDate
    41821
  • Firstpage
    2209
  • Lastpage
    2217
  • Abstract
    In this paper, we report on the development of an implantable pressure sensing system that is powered by mechanical vibrations in the audible acoustic frequency range. This technique significantly enhances interrogation range, alleviates the misalignment issues commonly encountered with inductive powering, and simplifies the external receiver circuitry. The interrogation scheme consists of two phases: a mechanical vibration phase and an electrical radiation phase. During the first phase, a piezoelectric cantilever acts as an acoustic receiver and charges a capacitor by converting sound vibration harmonics occurring at its resonant frequency into electrical power. In the subsequent electrical phase, when the cantilever is not vibrating, the stored electric charge is discharged across an LC tank whose inductor is pressure sensitive; hence, when the LC tank oscillates at its natural resonant frequency, it radiates a high-frequency signal that is detectable using an external receiver and its frequency corresponds to the measured pressure. The pressure sensitive inductor consists of a planar coil (single loop of wire) with a ferrite core whose distance to the coil varies with applied pressure. A prototype of the implantable pressure sensor is fabricated and tested, both in vitro and in vivo (swine bladder). A pressure sensitivity of 1 kHz/cm $H_{2}$O is achieved with minimal misalignment sensitivity (26% drop at 90° misalignment between the implanted device and acoustic source; 60% drop at 90° misalignment between the implanted device and RF receiver coil).
  • Keywords
    acoustic receivers; bioelectric potentials; biological organs; biomedical electronics; biomedical telemetry; cantilevers; capacitors; coils; electric charge; inductors; piezoelectric devices; pressure sensors; radio receivers; sensitivity; vibrations; wireless sensor networks; RF receiver coil; acoustic receiver; acoustic source; audible acoustic frequency range; capacitor; electrical power; electrical radiation phase; electromechanical interrogation scheme; external receiver; external receiver circuitry; ferrite core; high-frequency signal; implantable pressure sensing system; implanted device; inductive powering; mechanical vibration phase; minimal misalignment sensitivity; natural resonant frequency; piezoelectric cantilever; planar coil; pressure sensitive inductor; resonant frequency; single wire loop; sound vibration harmonics; subsequent electrical phase; swine bladder; Acoustics; Biomembranes; Coils; Ferrites; Receivers; Resonant frequency; Transponders; Acoustic powering; bladder pressure; implan- table pressure sensor; mechanical vibration;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2014.2318023
  • Filename
    6807758