DocumentCode
1774664
Title
Transformer winding losses with round conductors for duty-cycle regulated square waves
Author
Iyer, Kartik V. ; Robbins, William P. ; Basu, Kaustav ; Mohan, Ned
Author_Institution
Dept. of Electr. & Comput. Eng., Univ. of Minnesota, Minneapolis, MN, USA
fYear
2014
fDate
18-21 May 2014
Firstpage
3061
Lastpage
3066
Abstract
One of the limiting factor in the course of reducing the size of high frequency transformer is the temperature rise. The knowledge of transformer power loss is important to make an estimate of the temperature rise. The transformer winding loss due to a duty-cycle regulated square current waveform can be estimated by summing the copper loss due to each harmonic using Dowell´s formula. The paper shows that a large number of harmonics have to be considered for the loss computation. It is shown that for solid-round wire conductors the losses decrease with increasing diameter and there is no optimal diameter for which the losses are minimum. This paper presents a closed form approximate expression for power loss for a particular range of diameters of round wire that does not require a large series summation. Results from this closed form expression are shown to have reasonable accuracy in comparison to the fourier series method and also validated using 2-D finite element method.
Keywords
Fourier series; finite element analysis; high-frequency transformers; transformer windings; 2D finite element method; Dowell´s formula; duty-cycle regulated square current waveform; high frequency transformer; round conductors; solid-round wire conductors; temperature rise estimation; transformer winding loss; Conductors; Copper; Current density; Harmonic analysis; Solids; Windings; Wires;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Conference (IPEC-Hiroshima 2014 - ECCE-ASIA), 2014 International
Conference_Location
Hiroshima
Type
conf
DOI
10.1109/IPEC.2014.6870121
Filename
6870121