DocumentCode
1775752
Title
Type N RF calorimeter in coaxial line
Author
Chuanzhong Xu ; Chuntao Yang ; Yunmei Chen ; Lin Yang
Author_Institution
Radio Meas. Dept., Beijing Inst. of Radio Metrol. & Meas. Res., Beijing, China
fYear
2014
fDate
26-29 July 2014
Firstpage
864
Lastpage
867
Abstract
It´s more important to develop one high accuracy RF calorimeter for RF power standard at first. This document introduces a new type N RF calorimeter in coaxial line, in which the load, the transmission line, the temperature sensor and the structure by controlled temperature are key points to make high performance by series of testing data. To set up the RF power standard by the calorimeter, we discussed the evaluations on the power measurement uncertainty of the standard.
Keywords
calorimeters; coaxial cables; radiofrequency measurement; temperature sensors; transmission lines; RF power standard; coaxial line; power measurement uncertainty; temperature sensor; transmission line; type N RF calorimeter; Radio frequency; Standards; Temperature measurement; Temperature sensors; Thermal stability; Transmission line measurements; Uncertainty; RF calorimeter; high accurcy; power standard; stability;
fLanguage
English
Publisher
ieee
Conference_Titel
Antennas and Propagation (APCAP), 2014 3rd Asia-Pacific Conference on
Conference_Location
Harbin
Print_ISBN
978-1-4799-4355-5
Type
conf
DOI
10.1109/APCAP.2014.6992636
Filename
6992636