• DocumentCode
    1775752
  • Title

    Type N RF calorimeter in coaxial line

  • Author

    Chuanzhong Xu ; Chuntao Yang ; Yunmei Chen ; Lin Yang

  • Author_Institution
    Radio Meas. Dept., Beijing Inst. of Radio Metrol. & Meas. Res., Beijing, China
  • fYear
    2014
  • fDate
    26-29 July 2014
  • Firstpage
    864
  • Lastpage
    867
  • Abstract
    It´s more important to develop one high accuracy RF calorimeter for RF power standard at first. This document introduces a new type N RF calorimeter in coaxial line, in which the load, the transmission line, the temperature sensor and the structure by controlled temperature are key points to make high performance by series of testing data. To set up the RF power standard by the calorimeter, we discussed the evaluations on the power measurement uncertainty of the standard.
  • Keywords
    calorimeters; coaxial cables; radiofrequency measurement; temperature sensors; transmission lines; RF power standard; coaxial line; power measurement uncertainty; temperature sensor; transmission line; type N RF calorimeter; Radio frequency; Standards; Temperature measurement; Temperature sensors; Thermal stability; Transmission line measurements; Uncertainty; RF calorimeter; high accurcy; power standard; stability;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Antennas and Propagation (APCAP), 2014 3rd Asia-Pacific Conference on
  • Conference_Location
    Harbin
  • Print_ISBN
    978-1-4799-4355-5
  • Type

    conf

  • DOI
    10.1109/APCAP.2014.6992636
  • Filename
    6992636