DocumentCode
1778968
Title
Multipath Blind Routing Algorithm for Low-Voltage Power Line Communication Based on Improved Clustering
Author
Liu Xiao-Sheng ; Li Yan-Xiang ; Wang Juan ; Zhu Hong-Lin ; Xu Dian-Guo
Author_Institution
Sch. of Electr. Eng. & Autom., Harbin Inst. of Technol., Harbin, China
fYear
2014
fDate
18-20 Sept. 2014
Firstpage
578
Lastpage
583
Abstract
In view of the deficiency of existing power line networking algorithms, the paper proposes a novel improved clustering multipath blind routing algorithm, which meets the requirements of survivability and real-time, solves the problem of network reconstruction on link invalidation. Also, solutions to some abnormal situations, such as node joining and exiting are given. Finally, the validity and superiority of the algorithm is verified through simulations. The results show that the improved clustering algorithm proposed in this paper can achieve network construction and reconstruction rapidly and flexibly, which is of positive significance to improve the reliability of communication.
Keywords
carrier transmission on power lines; telecommunication network reliability; telecommunication network routing; clustering algorithm; link invalidation; multipath blind routing algorithm; network construction; network reconstruction; power line communication; power line networking algorithms; Clustering algorithms; Heuristic algorithms; Logic gates; Peer-to-peer computing; Relays; Reliability; Routing; low voltage power line; networking; reconstruction; routing algorithm;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation and Measurement, Computer, Communication and Control (IMCCC), 2014 Fourth International Conference on
Conference_Location
Harbin
Print_ISBN
978-1-4799-6574-8
Type
conf
DOI
10.1109/IMCCC.2014.124