DocumentCode
1800189
Title
Removal artifacts from EEG signal using independent component analysis and principal component analysis
Author
Turnip, Arjon ; Junaidi, Edy
Author_Institution
Tech. Implementation Unit for Instrum. Dev., Indonesian Inst. of Sci., Bandung, Indonesia
fYear
2014
fDate
19-21 Aug. 2014
Firstpage
296
Lastpage
302
Abstract
In recording the EEG signals are often contamination signal called artifacts. There are different kinds of artifacts such as power line noise, electromyogram (EMG), electrocardiogram (ECG) and electrooculogram (EOG). This research will compare two methods for removing artifacts, i.e. ICA and PCA methods. EEG signals are recorded on three conditions, which is normal conditions, closed eyes, and blinked eyes. After processing, the dominant frequency of the EEG signal is obtained in the range of 12-14 Hz (alpha-beta) either on normal conditions, closed eyes, and blinked eyes. From processing with ICA and PCA methods found that ICA method are better than PCA in terms of the separation of the EEG signals from mixed signals.
Keywords
electroencephalography; independent component analysis; medical signal processing; principal component analysis; EEG signal; EMG; EOG; ICA methods; PCA methods; blinked eyes condition; closed eyes condition; contamination signal; electrocardiogram; electromyogram; electrooculogram; independent component analysis; mixed signals; normal conditions; power line noise; principal component analysis; removal artifacts; signal frequency; Band-pass filters; Electrodes; Electroencephalography; Electrooculography; Feature extraction; Principal component analysis; Vectors; EEG; EOG; ICA; PCA;
fLanguage
English
Publisher
ieee
Conference_Titel
Technology, Informatics, Management, Engineering, and Environment (TIME-E), 2014 2nd International Conference on
Conference_Location
Bandung
Print_ISBN
978-1-4799-4806-2
Type
conf
DOI
10.1109/TIME-E.2014.7011635
Filename
7011635
Link To Document