• DocumentCode
    1804960
  • Title

    Neuron-based sensors for biochemical quantitation

  • Author

    Kisaalita, W.S. ; Skeen, R.S. ; Van Wie, B.J. ; Barnes, C.D. ; Fung, S.J. ; Davis, W.C.

  • Author_Institution
    Washington State Univ., Pullman, WA, USA
  • fYear
    1989
  • fDate
    9-12 Nov 1989
  • Firstpage
    1124
  • Abstract
    Using intracellular recording from freshly dissected Limnea stagnalis neurons and cultured clones for mouse neuroblastoma, N-18 and N1E-115, linear relationships between several analyte concentrations and neuron electrical properties, such as action potential, are obtained. This demonstrates the suitability of neurons as primary transducers in neuron-based sensors. Initial development work that will lead to testing cultured neurons for the detection of monoclonal antibodies is reported
  • Keywords
    bioelectric potentials; biosensors; chemioception; neurophysiology; Limnea stagnalis neurons; action potential; analyte concentrations; biochemical quantitation; biochips; cultured clones; intracellular recording; monoclonal antibodies; mouse neuroblastoma; neuron electrical properties; neuron-based sensors; primary transducers; Anatomy; Biosensors; Cloning; Delay; Ethanol; Mice; Monitoring; Neurons; Physiology; Transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1989. Images of the Twenty-First Century., Proceedings of the Annual International Conference of the IEEE Engineering in
  • Conference_Location
    Seattle, WA
  • Type

    conf

  • DOI
    10.1109/IEMBS.1989.96118
  • Filename
    96118