Abstract
Experimental investigations of breakdown in vacuum up to 7.6×10-6 Torr in weakly nonuniform fields with lightning impulse voltage of either polarity are reported in this paper. From the oscillograms taken for each impulse voltage application, measured results of statistical time lag, propagation of leader and breakdown characteristics with respect to Schwaiger factor are analysed
Keywords
impulse testing; insulation testing; lightning; vacuum breakdown; vacuum insulation; 7.6E-5 torr; Schwaiger factor; breakdown characteristics; leader propagation; negative lightning impulse voltages; oscillograms; positive lightning impulse voltages; statistical time lag; vacuum breakdown; weakly nonuniform fields; Breakdown voltage; Dielectrics; Electric breakdown; Lightning; Optical propagation; Oscilloscopes; Partial discharges; Vacuum breakdown; Vacuum technology; Voltage measurement;