• DocumentCode
    1817823
  • Title

    High coulombic thyratron development: test equipment and device performance

  • Author

    Pirrie, C.A. ; Gray, J.W.

  • Author_Institution
    EEV Ltd., Chelmsford, UK
  • fYear
    1996
  • fDate
    35137
  • Firstpage
    42491
  • Lastpage
    42493
  • Abstract
    A thyratron-like device capable of conducting multi-kiloamp multi-coulomb current pulses for high energy capacitor bank discharge applications is currently under development. The development phase has necessitated the design, construction and commissioning of an appropriate test equipment with parameters which closely simulate those of one of the intended applications. Both the test equipment and the progress to date on the pulsed power switch development are described by the authors
  • Keywords
    pulse generators; pulsed power switches; test equipment; thyratrons; applications; commissioning; construction; current pulses; design; device performance; power capacitor bank discharge; pulsed power switch development; test equipment; thyratron;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Pulsed Power '96, IEE Colloquium on
  • Conference_Location
    London
  • Type

    conf

  • DOI
    10.1049/ic:19960379
  • Filename
    542937