Abstract
This paper presents a control strategy for four-leg grid-connected PWM rectifiers that have an active power filtering function. The four-leg voltage source converter topology gives ability to control an input current in the neutral leg. That is important for the active power filtering function when there is an unbalanced load. The control strategy is based on a voltage oriented method that has a cascaded DC voltage and current controllers designed in a rotating reference frame. The DC voltage controller is a PI-type, whereas the input current is shaped by a full-state feedback controller. The novelty of the proposed solution is the control structure that has modified the DC voltage error signal by adding a discontinuity element and reduction the number of current signals by half. The discontinuity element is needed to provide a constant reference current signal during active power filtering operation. The paper describes in detail the design procedure for the voltage and current controllers. Numerical results for active rectification and active power filtering operations are presented and discussed. Numerical results have been obtained by using a discrete control model.
Keywords
PWM rectifiers; electric current control; power filters; power grids; rectification; state-space methods; voltage regulators; DC voltage controller; DC voltage error signal; PI-type controller; active power filtering function; active rectification; cascaded DC voltage; constant reference current signal; discontinuity element; discrete control model; four-leg grid-connected PWM rectifiers; four-leg voltage source converter topology; full-state feedback controller; neutral leg; rotating reference frame; state-space current control; unbalanced load; voltage oriented method; Current control; Current measurement; Power conversion; Pulse width modulation; Sensors; Voltage control; 4-Leg Voltage Source Converter; Active Power Filter; Grid-Connected PWM Rectifier; LQ controller;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics and Motion Control Conference and Exposition (PEMC), 2014 16th International
Conference_Location
Antalya
Type
conf
DOI
10.1109/EPEPEMC.2014.6980686
Filename
6980686
Link To Document