DocumentCode
1827118
Title
Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET
Author
Livieratos, L. ; Stegger, L. ; Bloomfield, P.M. ; Schafers, K. ; Bailey, D.L. ; Camici, P.G.
Author_Institution
MRC Clinical Sci. Centre, Hammersmith Hosp., London, UK
Volume
3
fYear
2003
fDate
19-25 Oct. 2003
Firstpage
2183
Abstract
Respiratory motion is a source of artefacts and quantification errors in cardiac imaging. Preliminary studies with retrospective respiratory gating in PET support the observation of other imaging modalities of a rigid-body motion of the heart during respiration. However, the use of gating techniques to eliminate motion may result in poor count statistics per reconstructed image. We have implemented a motion correction technique which applies rigid-body transformations on list-mode data event-by-event on the basis of a geometric model of intersection of the lines-of-response with the scanner. Pre-correction for detector efficiencies and photon attenuation before transformation are included in the process. Projection data are acquired together with physiological signal (every ms) from an inductive respiration monitor with an elasticised belt at chest level. Data are retrospectively sorted into separate respiratory gates on an off-line workstation. Transformation parameters relating the gated images, estimated by means of image registration, can be applied on the original list-mode data to obtain a single motion-corrected dataset. The accuracy of the technique was assessed with point source data and a good correlation between applied and measured transformations, estimated from the centroid of the source, was observed. The technique was applied on phantom data with simulated respiratory motion and on patient data with C15O and 18FDG. Quantitative assessment of preliminary C15O patient datasets showed at least 4.5% improvement in the recovery coefficient at the centre of the left ventricle.
Keywords
cardiovascular system; image motion analysis; image reconstruction; image registration; medical image processing; phantoms; pneumodynamics; positron emission tomography; cardiac PET; heart; image reconstruction; image registration; list-mode projection data; phantom data; photon attenuation; physiological signal; respiratory motion correction; retrospective respiratory gating; rigid-body transformation; Attenuation; Belts; Biomedical monitoring; Detectors; Heart; Image reconstruction; Positron emission tomography; Solid modeling; Statistics; Workstations;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2003 IEEE
ISSN
1082-3654
Print_ISBN
0-7803-8257-9
Type
conf
DOI
10.1109/NSSMIC.2003.1352313
Filename
1352313
Link To Document