• DocumentCode
    1827507
  • Title

    Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography

  • Author

    Hyonyoung Han ; Min-Joon Kim ; Jung Kim

  • Author_Institution
    Korea Adv. Inst. of Sci. & Technol., Daejeon
  • fYear
    2007
  • fDate
    22-26 Aug. 2007
  • Firstpage
    1538
  • Lastpage
    1541
  • Abstract
    This paper presents a motion artifact reduction algorithm for a real-time, wireless and wearable photoplethysmography (PPG) device for measuring heart beats. A wearable finger band PPG device consists of a 3-axis accelerometer, infrared LED, photo diode, a microprocessor and wireless module. Sources of the motion artifacts were investigated from the hand motions, through computing the correlations between the three directional finger motions and distorted PPG signals. A two-dimensional active noise cancellation algorithm was applied to compensate the distorted signals by motions, using the directional accelerometer data. NLMS (Normalized Least Mean Square) adaptive filter (4th order) was employed in the algorithm. As a result, the signals´ distortion rates were reduced from 52.34% to 3.53%, at frequencies between 1 and 2.5 Hz, which representing daily motions such walking and jogging. The wearable health monitoring device equipped with the motion artifact reduction algorithm can be integrated as a terminal in a so-called ubiquitous healthcare system, which provides a continuous health monitoring without interrupting a daily life.
  • Keywords
    active filters; biomedical equipment; distortion; gait analysis; health care; interference suppression; least mean squares methods; medical signal processing; patient monitoring; plethysmography; NLMS; accelerometer; active noise cancellation algorithm; adaptive filter; continuous health monitoring; frequency 1 Hz to 2.5 Hz; hand motion; heart beat measurement; infrared LED; microprocessor; normalized least mean square; photo diode; real-time motion artifact reduction algorithm; signal distortion; ubiquitous healthcare system; wearable finger band PPG device; wearable health monitoring device; wearable photoplethysmography; wireless PPG device; Accelerometers; Adaptive filters; Biomedical monitoring; Distortion measurement; Fingers; Heart beat; Light emitting diodes; Microprocessors; Motion measurement; Noise cancellation; Algorithms; Artifacts; Diagnosis, Computer-Assisted; Heart Rate; Humans; Monitoring, Ambulatory; Motion; Photoplethysmography; Reproducibility of Results; Sensitivity and Specificity;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE
  • Conference_Location
    Lyon
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-0787-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.2007.4352596
  • Filename
    4352596