• DocumentCode
    1838654
  • Title

    Irradiation adaptation to the tumor activity with the help of Intensity-Modulated Radiation Therapy for head and neck cancers

  • Author

    Kubs, F. ; Aletti, P. ; Wolf, D. ; Millasseau, S. ; Marchesi, V.

  • Author_Institution
    Nancy-Univ., Nancy
  • fYear
    2007
  • fDate
    22-26 Aug. 2007
  • Firstpage
    3434
  • Lastpage
    3437
  • Abstract
    The aim of this study was to set up the appropriate geometry to perform a high-precision irradiation, based on tumor activity (TA). The elaboration of a new treatment protocol based on TA required a specific geometry in order to use this type of irradiation. Using a treatment planning system TPS and two head and neck phantoms specially created, we have performed TPS characterization according to different treatment plans. Two models were created and used: a simplistic and an anatomical model. Our results showed that high-precision radiotherapy in limited zones is possible with intensity modulated radiation therapy (IMRT) when several conditions such as location, number of organs at risk (OAR´s), distance between planning target volume (PTV) and OAR, presence, volume and location of the TA, number of fields are met. In order to use this irradiation method adapted to the TA, a precise geometry will be necessary. However such high total and fractionated doses should be carefully evaluated before being prescribed clinically.
  • Keywords
    biological organs; cancer; dosimetry; intensity modulation; phantoms; radiation therapy; tumours; IMRT; fractionated doses; head-and-neck cancers; head-and-neck phantoms; high-precision radiotherapy; intensity-modulated radiation therapy; irradiation adaptation; organs at risk; target volume planning; treatment planning system; treatment protocols; tumor activity; Biomedical applications of radiation; Biomedical imaging; Cancer; Geometry; Head; Neck; Neoplasms; Physics; Positron emission tomography; TV; Computer Simulation; Head and Neck Neoplasms; Humans; Models, Biological; Radiometry; Radiotherapy Dosage; Radiotherapy Planning, Computer-Assisted; Radiotherapy, Computer-Assisted; Radiotherapy, Conformal; Relative Biological Effectiveness;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE
  • Conference_Location
    Lyon
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-0787-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.2007.4353069
  • Filename
    4353069