• DocumentCode
    1847041
  • Title

    Tensile strength of electrical insulating paper in natural ester and mineral oil

  • Author

    Shim, Meoung-Seop ; Jung, Joong-Il ; An, Jung-Sik ; Choi, Sun-Ho ; Seo, Yu-Jin ; Huh, Chang-Su

  • Author_Institution
    Dept. of Electr. Eng., Inha Univ., Incheon, South Korea
  • fYear
    2010
  • fDate
    23-24 June 2010
  • Firstpage
    563
  • Lastpage
    565
  • Abstract
    Aging of transformer insulating material in natural ester insulating oil was compared to that in conventional transformer oil. Aging of insulating paper has been studied by performing accelerated thermal aging test. Sealed aging test vessels containing copper, laminated core, Kraft/Diamond paper, and insulating oil (natural oil or mineral oil) were aged at 140°C during 500, 1000 and 1500 hours. The extent of paper degradation after aging was determined using paper tensile strength in the aged fluid. The Kraft/Diamond Paper aged in conventional transformer oil degraded at a significantly faster rate than in natural ester insulating oil.
  • Keywords
    ageing; insulating materials; life testing; power transformer testing; tensile strength; transformer oil; accelerated thermal aging test; aged fluid; electrical insulating paper; mineral oil; natural ester; temperature 140 degC; tensile strength; time 1000 hour; time 1500 hour; time 500 hour; transformer insulating material; transformer oil; Aging; Electrical engineering; Minerals; Oil insulation; Petroleum; Power transformer insulation; dielectric liquids; dielectric materials; natural ester; oil insulation; power transformers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering and Optimization Conference (PEOCO), 2010 4th International
  • Conference_Location
    Shah Alam
  • Print_ISBN
    978-1-4244-7127-0
  • Type

    conf

  • DOI
    10.1109/PEOCO.2010.5559209
  • Filename
    5559209