• DocumentCode
    1858808
  • Title

    Sensitive chlorine gas detection at the sub-ppm level using nanophase-separated amphiphilic co-networks as highly convenient matrices

  • Author

    Meskath, S. ; Heinze, J. ; Urban, G.

  • Author_Institution
    Freiburg Mater. Res. Center, Univ. of Freiburg, Freiburg, Germany
  • fYear
    2009
  • fDate
    21-25 June 2009
  • Firstpage
    1834
  • Lastpage
    1837
  • Abstract
    Amphiphilic polymer conetworks (APCN) are used as sensor matrices for rapid chlorine gas detection. The APCNs were synthesized by free radical induced photopolymerization and result in poly(2-hydoxyethyl acrylate)-l-polydimethylsiloxan (PHEA-l-PDMS). Easy impregnation of the polymer thin films with o-tolidine as oxidation indicator makes them sensitive for chlorine gas with detection times within seconds.
  • Keywords
    chemical variables measurement; gas sensors; polymerisation; polymers; PHEA-l-PDMS; amphiphilic polymer conetworks; chlorine gas detection; convenient matrices; nanophase-separated amphiphilic co-networks; o-tolidine; oxidation indicator; photopolymerization; poly(2-hydoxyethyl acrylate)-l-polydimethylsiloxan; polymer thin films; sensor matrices; sub-ppm level; Gas detectors; Oxidation; Polymer films; Amphiphilic conetworks; chlorine; copolymer networks; gas sensor; nanophase-separation; polysiloxane; silicon-hydrogels;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Solid-State Sensors, Actuators and Microsystems Conference, 2009. TRANSDUCERS 2009. International
  • Conference_Location
    Denver, CO
  • Print_ISBN
    978-1-4244-4190-7
  • Electronic_ISBN
    978-1-4244-4193-8
  • Type

    conf

  • DOI
    10.1109/SENSOR.2009.5285702
  • Filename
    5285702