DocumentCode
1860963
Title
Accuracy verification of impulse voltage measuring systems by convolution methods
Author
Yutthagowith, P. ; Pattanadech, N. ; Kunakorn, A. ; Phoomvuthisarn, S.
Author_Institution
Center of Excellence in Electr. Power Technol., Chulalongkorn Univ., Bangkok
fYear
2005
fDate
Nov. 29 2005-Dec. 2 2005
Firstpage
1
Lastpage
333
Abstract
This paper presents verification of high voltage measuring systems by time convolutions between standard testing waveforms and unit step responses of the measuring systems. The waveforms under investigations are full lightning impulse voltage waveforms, tail-chopped lightning impulse voltage waveforms, front-chopped lightning impulse voltage waveforms and steep-front voltage waveforms according to IEC standards 60060-2 and 61211. This paper considers four different types of the measuring systems. The results show that this technique is applicable, and should be a useful method for impulse voltage measurements in a standard high voltage
Keywords
lightning; voltage measurement; IEC standards; impulse voltage measuring systems; lightning impulse voltage waveforms; step responses; time convolution methods; Circuit testing; Convolution; IEC standards; Impulse testing; Instruments; Lightning; Measurement standards; System testing; Time measurement; Voltage measurement; convolutions; impulse voltage measurements;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Engineering Conference, 2005. IPEC 2005. The 7th International
Conference_Location
Singapore
Print_ISBN
981-05-5702-7
Type
conf
DOI
10.1109/IPEC.2005.206930
Filename
1627219
Link To Document