• DocumentCode
    1869108
  • Title

    Model reduction of electric load simulator

  • Author

    Shan Han ; Jianxun Li ; Jianfang Dou

  • Author_Institution
    Department of Automation, Shanghai Jiao Tong University, Ministry of Education of China, 200240
  • fYear
    2012
  • fDate
    3-5 March 2012
  • Firstpage
    1355
  • Lastpage
    1359
  • Abstract
    Because of the limitation of linear controllers used in the present development stage, model reduction of electric load simulator with a high-order nonlinear model becomes the basis of control system design. To solve this problem, Balanced Truncation is proposed in this paper as the improvement of traditional Dominant Poles for model reduction. An analysis method of model reduction error based on H∞ norm is also researched to evaluate the reduction effect of different ways. A synthesis error including linearization error and order reduction error can be obtained and analysed finally. Compared with Dominant Poles, the superiority of Balanced Truncation in model reduction of electric load simulator is testified by the experimental verification.
  • Keywords
    Electric load simulator; error analysis; high-order nonlinear system; model reduction;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Automatic Control and Artificial Intelligence (ACAI 2012), International Conference on
  • Conference_Location
    Xiamen
  • Electronic_ISBN
    978-1-84919-537-9
  • Type

    conf

  • DOI
    10.1049/cp.2012.1231
  • Filename
    6492838