• DocumentCode
    1877067
  • Title

    Investigation on the Response of the Human Eye to the Light Flicker Produced by Different Lamps

  • Author

    Peretto, Lorenzo ; Rovati, Luigi ; Salvatori, Giorgia ; Tinarelli, Roberto ; Emanuel, Alexander E.

  • Author_Institution
    Dipt. di Ingegneria Elettrica, Universita di Bologna
  • fYear
    2006
  • fDate
    24-27 April 2006
  • Firstpage
    37
  • Lastpage
    42
  • Abstract
    The response of the human eye to flicker depends on the type of lamp used. The standard flickermeter is based on the measurement of voltage and assumes the light source to be a 60 W incandescent lamp. When a different lamp is the source of light flicker, the standard flickermeter gives erroneous results. This paper presents a dynamic model of the eye-brain response to flicker. The model is based on the analysis of the light emitted by the lamp. A suitable measurement system has been developed and three different kinds of lamps have been considered. Experimental results show how the emitted light spectra and the human eye response to different colors determine the level of annoyance
  • Keywords
    brain; eye; filament lamps; visual perception; 60 W; emitted light spectra; eye-brain response; flickermeter; human eye; incandescent lamp; light flicker; light source; voltage measurement; Analytical models; Apertures; Chemical elements; Humans; Iris; Lamps; Measurement standards; Muscles; Retina; Voltage fluctuations; eye-brain response; light flicker; power quality;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 2006. IMTC 2006. Proceedings of the IEEE
  • Conference_Location
    Sorrento
  • ISSN
    1091-5281
  • Print_ISBN
    0-7803-9359-7
  • Electronic_ISBN
    1091-5281
  • Type

    conf

  • DOI
    10.1109/IMTC.2006.328169
  • Filename
    4124271