RHIC injection kicker impedance
Author
Mane, V. ; Peggs, S. ; Trbojevic, D. ; Zhang, W.
Author_Institution
Brookhaven Nat. Lab., Upton, NY, USA
Volume
5
fYear
1995
fDate
1-5 May 1995
Firstpage
3134
Abstract
The longitudinal impedance of the RHIC injection kicker is measured using the wire method upto a frequency of 3 GHz. The mismatch between the 50 ohm cable and the wire and pipe system is calibrated using the TRL calibration algorithm. Various methods of reducing the impedance, such as coated ceramic pipe and copper strips are investigated
Keywords
beam handling equipment; calibration; colliding beam accelerators; electric impedance; ion accelerators; particle beam diagnostics; particle beam injection; storage rings; synchrotrons; 3 GHz; 50 ohm; Cu; Cu strips; RHIC injection kicker impedance; Relativistic Heavy Ion Collider; TRL calibration algorithm; cable; coated ceramic pipe; impedance reduction; longitudinal impedance; mismatch; wire method; Calibration; Ceramics; Conductors; Ferrites; Frequency measurement; Impedance measurement; Length measurement; Performance evaluation; Power cables; Wire;