Radiated immunity measurement comparison between OSL and chamber
Author
Jang, Tae Heon ; Cho, Won Seo
Author_Institution
EMC Team, Korea Testing Lab., Seoul
fYear
2006
fDate
Feb. 27 2006-March 3 2006
Firstpage
477
Lastpage
480
Abstract
In CISPR 20, radiated immunity test is performed in the open stripline (OSL) which height is 0.8 m. CISPR 20 also specifies that equipment not fitting inside open stripline shall be measured according to IEC 61000-4-3 in frequency range of 80 MHz to 150 MHz with the same limits as in the OSL. In this paper, the analysis of the field distribution in the OSL was completed by moment method and the testing according to both methods was carried out and the immunity level has compared. The result shows that the testing in chamber is more severe than in OSL
Keywords
anechoic chambers (electromagnetic); immunity testing; method of moments; strip lines; 80 to 150 MHz; OSL; moment method; open stripline; radiated immunity measurement; radiated immunity test; Conductors; Electromagnetic analysis; Electromagnetic compatibility; Frequency; IEC standards; Immunity testing; Laboratories; Moment methods; Stripline; TV receivers;