• DocumentCode
    1910793
  • Title

    Performance prediction of shaded pole induction motors

  • Author

    Osheiba, A.M. ; Ahmed, K.A. ; Rahman, M.A.

  • Author_Institution
    Fac. of Eng., Monoufia Univ., Shebin El-Kom, Egypt
  • fYear
    1989
  • fDate
    1-5 Oct. 1989
  • Firstpage
    158
  • Abstract
    An analysis is presented for evaluating the performance characteristics of reluctance-augmented shaded pole motors. The proposed model is based on the d-q axis technique and is valid for steady-state and dynamic conditions. Further, an efficient method for predicting the steady-state operating characteristics of the triac controlled shaded pole motor is presented. The method is used to calculate the effective currents and average torque as functions of the conduction and control angles of the triac. Careful attention is paid to the effects of critical parameters on motor performance. Simulated results show close agreement with the results of experimental tests of a two-pole single-phase induction motor.<>
  • Keywords
    induction motors; d-q axis technique; dynamic conditions; performance characteristics; reluctance-augmented shaded pole motors; shaded pole induction motors; steady-state operating characteristics; Air gaps; Circuits; Coils; Equations; Hysteresis motors; Induction motors; Performance analysis; Reluctance motors; Stator windings; Steady-state;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industry Applications Society Annual Meeting, 1989., Conference Record of the 1989 IEEE
  • Conference_Location
    San Diego, CA, USA
  • Type

    conf

  • DOI
    10.1109/IAS.1989.96646
  • Filename
    96646