• DocumentCode
    1914870
  • Title

    Monitoring of Overhead Contact Line Based on Contact Force

  • Author

    Harada, Satoshi ; Kusumi, Shunichi

  • Author_Institution
    Div. of Power Supply Technol., Railway Tech. Res. Inst.
  • fYear
    2006
  • fDate
    29-30 Nov. 2006
  • Firstpage
    188
  • Lastpage
    193
  • Abstract
    Large contact force fluctuations between contact wires and pantographs cause unstable current collection conditions, therefore, it is important to measure and estimate the contact force to obtain a better knowledge of current collection quality. Contact force waveforms are affected by the condition of equipment used on overhead contact lines, therefore, it is anticipated that the contact force waveform represent improvable points of the overhead contact line. This paper describes the characteristics of contact force waveform against the static height of contact wires at Shinkansen and their applications in overhead line diagnosis
  • Keywords
    condition monitoring; mechanical contact; pantographs; railway engineering; Shinkansen; contact force fluctuations; contact wires; current collection quality; overhead contact line monitoring; overhead line diagnosis; pantographs; unstable current collection conditions; contact force; presumption for sliding materials; state of overhead contact lines;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Railway Condition Monitoring, 2006. The Institution of Engineering and Technology International Conference on
  • Conference_Location
    Birmingham
  • Print_ISBN
    0-86341-732-9
  • Type

    conf

  • Filename
    4126758