• DocumentCode
    1935668
  • Title

    Design of a microinductive device integrated within a simple resonant differential filter for high sensitivity portable biodetectors

  • Author

    Martínez, S. ; Perez-Rodriguez, Alejandro ; Serre, Catherine ; Morante, J.R. ; Esteve, J. ; Montserrat, J.

  • Author_Institution
    Dept. Electronica, Univ. de Barcelona, Spain
  • fYear
    2005
  • fDate
    2-4 Feb. 2005
  • Firstpage
    521
  • Lastpage
    524
  • Abstract
    This work describes the design and characterization of Si technology microinductive devices to be integrated within resonant differential filters for high sensitivity detection of biological molecules. The simulation of these simple circuits shows sensitivity values of the differential output voltage up to 339 mV/nH. This has allowed to detect down to about 2700 magnetic particles per mm 2, which corresponds to a minimum detectable concentration of the analyte in the range 8×10 -13 to 6×10 -14 M, compatible with high sensitivity biodetection requirements.
  • Keywords
    biosensors; high-pass filters; magnetic particles; microsensors; molecular biophysics; sensitivity analysis; silicon; Si; Si technology; biological molecules; differential output voltage; high sensitivity detection; magnetic particles; microinductive device; portable biodetectors; resonant differential filter; Biosensors; Circuit simulation; Coils; Filters; Frequency; Inductance; RLC circuits; Resonance; Transfer functions; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electron Devices, 2005 Spanish Conference on
  • Conference_Location
    Tarragona
  • Print_ISBN
    0-7803-8810-0
  • Type

    conf

  • DOI
    10.1109/SCED.2005.1504504
  • Filename
    1504504