Abstract
A method of measuring the voltage produced by a helical explosive flux compression generator using a remote electric field antenna is described in detail. The diagnostic has been successfully implemented on several experiments. Measured data from the diagnostic compare favorably with voltages predicted using the code CAGEN [1], validating our predictive modeling tools. The measured data is important to understanding generator performance, and is measured with a low-risk, minimally intrusive approach.
Keywords
electric field effects; helical antennas; voltage measurement; code CAGEN; helical FCG voltage; helical explosive flux compression generator; remote electric field antenna; voltage measurement; Antenna measurements; Antennas; Capacitors; Coils; Current measurement; Generators; Voltage measurement;