• DocumentCode
    1957047
  • Title

    Effect of contamination on copper migration in TAB tape structures

  • Author

    Nieman, D.A.

  • Author_Institution
    Intel Corp., Chandler, AZ, USA
  • fYear
    1994
  • fDate
    11-14 April 1994
  • Firstpage
    87
  • Lastpage
    92
  • Abstract
    Copper migration in adhesive of Tape Automated Bonding (TAB) tape during biased moisture stress can cause failure. Experiments aimed at reducing copper migration show that copper precipitation lengths after HAST are linearly proportional to chloride concentration in the TAB tape material. Discharge potential measurements of TAB tape in 156 /spl deg/C bake are correlated to chloride concentration.<>
  • Keywords
    circuit reliability; failure analysis; integrated circuit testing; tape automated bonding; 156 degC; HAST; TAB tape structures; adhesive; biased moisture stress; chloride concentration; copper migration; discharge potential measurements; precipitation lengths; Clamps; Conducting materials; Conductors; Contamination; Copper; Packaging; Performance evaluation; Plastics; Stress; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Reliability Physics Symposium, 1994. 32nd Annual Proceedings., IEEE International
  • Conference_Location
    San Jose, CA, USA
  • Print_ISBN
    0-7803-1357-7
  • Type

    conf

  • DOI
    10.1109/RELPHY.1994.307852
  • Filename
    307852