DocumentCode
1970479
Title
The CEBAF analog monitoring system
Author
Crawford, K. ; O´Sullivan, M. ; Perry, J. ; Simrock, S.
Author_Institution
Continuous Electron Beam Accel. Facility, Newport News, VA, USA
fYear
1993
fDate
17-20 May 1993
Firstpage
1925
Abstract
The purpose of the analog monitoring system (AMS) is to provide CEBAF operators the ability to monitor voltage signals from the RF control modules, beam loss monitors, and other dedicated systems from the accelerator service buildings with a 10 MHz (-1 dB), bandwidth. The signals are presented at the AMS receiving crate in the Machine Control Center (MCC). The system, when completed, will allow the operator to monitor any 4 signals from available channels in each location. At present these locations provide 800 signals in each of the linacs, 16 signals in each of the arcs, 120 signals in the injector, and 16 signals in the beam switchyard. This provides a total capacity of 1768 signals, with an upgrade ability of 3740 total signal capacity
Keywords
beam handling techniques; electron accelerators; linear accelerators; particle beam diagnostics; physical instrumentation control; voltage measurement; 10 MHz; AMS receiving crate; CEBAF analog monitoring system; Machine Control Center; RF control modules; accelerator service buildings; arcs; beam loss monitors; beam switchyard; dedicated systems; injector; linacs; upgrade ability; voltage signals monitoring; Linear accelerators; Monitoring; Optical fibers; Particle beams; Phase measurement; Phase modulation; RF signals; Radio frequency; Switches; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location
Washington, DC
Print_ISBN
0-7803-1203-1
Type
conf
DOI
10.1109/PAC.1993.309179
Filename
309179
Link To Document