• DocumentCode
    1971760
  • Title

    Beam energy measurement using the Hall C beamline (CEBAF)

  • Author

    Yan, C. ; Carlini, R. ; Neuffer, D.

  • Author_Institution
    Continuous Electron Beam Accel. Facility, Newport News, VA, USA
  • fYear
    1993
  • fDate
    17-20 May 1993
  • Firstpage
    2136
  • Abstract
    We propose to use the curved transport line into Hall C at CEBAF to measure the beam energy. With only dipoles powered, this transport arc has a dispersion of 12 cm/%. We propose to insert pairs of wire scanners at the entrance and exit of the arc to measure beam position and direction. These measurements, together with a calibrated dipole field, obtain an absolute beam energy measurement with ~10-3 accuracy, according to error analyses. In operational mode, arc quads and sextupoles are powered to obtain a second order achromat with a dispersion of 2.1 cm/% at the arc center. A wire scanner at the arc center then obtains a relative energy measurement of ~10-4 accuracy
  • Keywords
    electron accelerators; linear accelerators; particle beam diagnostics; position measurement; CEBAF; Hall C beamline; beam direction; beam energy measurement; beam position; quadrupoles; sextupoles; wire scanners; Dispersion; Electron accelerators; Electron beams; Energy measurement; Error analysis; Magnetic field measurement; Magnets; Particle beams; Position measurement; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1993., Proceedings of the 1993
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-7803-1203-1
  • Type

    conf

  • DOI
    10.1109/PAC.1993.309246
  • Filename
    309246