DocumentCode
1973458
Title
Sampling Cathode-Ray Tube Device for Microwave Waveform Analysis
Author
Fujisawa, Kazuo ; Yamamoto, Yukio ; Ito, Tetsuji ; Iwai, Toru
Author_Institution
Faculty of Engineering Science, Osaka University, Machikaneyama-Cho, Toyonaka, Osaka, Japan.
fYear
1978
fDate
4-8 Sept. 1978
Firstpage
508
Lastpage
512
Abstract
This device is to visualize waveform analysis up to mm-waves. The operation is based on two distinctive principles. The first is the sampling of the waveform by a repeated electron beam pulse synchronous with it. The second is the usage of a negative feed back system, which cancells the r.f. deflection of the electron beam pulse by a d.c.control voltage, the latter being proportional to the sampled wave-amplitude and thus giving information to it. The waveform is reproduced by plotting the above control voltage versus the phase position of the sampling. An experimental tube was designed and built to be used up to K-band. It was tested in X-band, and showed good characteristics.
Keywords
Cathode ray tubes; Control systems; Electron beams; Feeds; Microwave devices; Proportional control; Pulse circuits; Sampling methods; Structural beams; Voltage control;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Conference, 1978. 8th European
Conference_Location
Paris, France
Type
conf
DOI
10.1109/EUMA.1978.332583
Filename