• DocumentCode
    1978188
  • Title

    Swept Measurement of Screening Effectiveness of Connectors at RF and Microwave Frequencies

  • Author

    Stäger, Christian ; Bolinger, Walter

  • Author_Institution
    Swiss Post Office, Telecommunications Research and Development Division, CH-3030 Bern Switzerland
  • fYear
    1980
  • fDate
    8-12 Sept. 1980
  • Firstpage
    268
  • Lastpage
    272
  • Abstract
    A new measuring principle of screening effectiveness of coaxial connectors allows swept measurements in Z0 matched systems. The frequency range for the triaxial arrangement is 10 MHz to several GHz, depending only on the connector size. With the waveguide setup screening effectiveness swept measurements up to 18 GHz are possible. The combination tracking Generator - Spectrum Analyzer - Low noise amplifier - power amplifier allows a high dynamic range and broadband frequency coverage.
  • Keywords
    Broadband amplifiers; Coaxial components; Connectors; Frequency measurement; High power amplifiers; Low-noise amplifiers; Microwave frequencies; Microwave measurements; Power generation; Radio frequency;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Conference, 1980. 10th European
  • Conference_Location
    Warszawa, Poland
  • Type

    conf

  • DOI
    10.1109/EUMA.1980.332844
  • Filename
    4131492