• DocumentCode
    1978926
  • Title

    Positive hydrogen ion beam production by an RF-driven multicusp source

  • Author

    Leung, K.N. ; Bachman, D.A. ; Herz, P.R. ; McDonald, D.S. ; Olivo, M. ; Perkins, L.T.

  • Author_Institution
    Lawrence Berkeley Lab., California Univ., Berkeley, CA, USA
  • fYear
    1993
  • fDate
    17-20 May 1993
  • Firstpage
    3190
  • Abstract
    A 10 cm-diam RF-driven multicusp ion source has been tested for positive (H+) ion production in cw mode for future use in the 870 keV Cockcroft-Walton preinjector at the Paul Scherrer Institute. The source is optimized for the best atomic hydrogen ion species and extractable current. It is found that the porcelain coating on the antenna is very durable and stays intact after days of continuous operation. It is expected that the antenna will have a very long lifetime for an RF input power of ~6 kW
  • Keywords
    ion sources; 10 cm; 6 kW; Cockcroft-Walton preinjector; H; H+ source; RF-driven multicusp source; lifetime; porcelain coating; Copper; Hydrogen; Ion beams; Ion sources; Laboratories; Magnets; Plasma sources; Porcelain; Production; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1993., Proceedings of the 1993
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-7803-1203-1
  • Type

    conf

  • DOI
    10.1109/PAC.1993.309596
  • Filename