• DocumentCode
    1979049
  • Title

    Etiology of decubitus ulcers using an animal model - a comparison of blood flow measurement method between point analysis and two-dimensional analysis

  • Author

    Niitsuma, Junako ; Yano, Hideo ; Togawa, Tatsuo

  • Author_Institution
    Nat. Rehabilitation Center for the Disabled, Saitama, Japan
  • Volume
    4
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    3416
  • Abstract
    The purpose of this study has been to clarify the effect of sustained compression on skin surface blood flow at the edema stage and flare in the initial phase of decubitus ulcer formation with the use of rabbit ears. Experimental protocol is compared between point analysis and two-dimensional analysis. For the point analysis, a laser Doppler perfusion monitoring probe is contacted with the skin surface continuously. For two-dimensional analysis, the scanning probe is not contacted with skin. The experimental phases are divided as follows: 1) initial (pre-compression), 2) edema, 3) compression and 4) release from compression. For the the point analysis, the blood flow rate has been measured continuously on a point from the initial phase to release from the compression phase. When the two protocols were compared, similar blood flow changes were observed. From results of two-dimensional analysis, during the compression phase and during release from compression, the blood flow rate in the peripheral part of the compressed area was found to change proportionately to the applied compressive load.
  • Keywords
    biomechanics; blood flow measurement; haemorheology; laser applications in medicine; patient care; patient monitoring; skin; animal model; applied compressive load; blood flow measurement; blood flow rate; compression phase; decubitus ulcer formation; edema stage; etiology; flare; initial phase; laser Doppler perfusion monitoring probe; peripheral part; point analysis; pre-compression; rabbit ears; release from compression; scanning probe; skin surface; skin surface blood flow; sustained compression; two-dimensional analysis; Animals; Blood flow; Ear; Fluid flow measurement; Monitoring; Probes; Protocols; Rabbits; Skin; Surface emitting lasers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2001. Proceedings of the 23rd Annual International Conference of the IEEE
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-7211-5
  • Type

    conf

  • DOI
    10.1109/IEMBS.2001.1019563
  • Filename
    1019563