This note reports results from the commissioning of three systems in the AGS Booster: the beam position monitor system, which works to a relative accuracy of 0.36 millimeters; the uncorrected Booster orbit, which has quite large excursions; and the passive eddy current correction system, which eliminates all but a few percent of the eddy current dipole effect
Keywords
beam handling techniques; proton accelerators; synchrotrons; tuning; AGS Booster orbit system; beam position monitor system; commissioning; eddy current dipole effect; passive eddy current correction system; uncorrected Booster orbit; Current measurement; Eddy currents; Extraterrestrial measurements; Fitting; Gaussian processes; Laboratories; Magnetic fields; Monitoring; Particle beams; Position measurement;