• DocumentCode
    1994202
  • Title

    Emtremely Broadband Rf-Coonnector and Cable Screening Measurements (Up to 150 Db Screening Attenuation) for Frequencies of 1 KHz to 10 GHz

  • Author

    Eicher, B. ; Stäger, C.

  • fYear
    1985
  • fDate
    9-13 Sept. 1985
  • Firstpage
    887
  • Lastpage
    894
  • Abstract
    With a new, broadband matched test set-up, cable and connector screening effectiveness measurements over more than 7 frequency decades can be performed. The set-up allows to measure directive effects, which occur on both cables and connectors due to several discrete leakage points. High dynamic range (up to 150 dB) is achieved by using a combination of synthesized signal generator, synthesized spectrum analyzer and low noise preamplifier. This set-up will be introduced as the standard test method for connector screening effectiveness measurements by IEC and is also suitable for cable measurements.
  • Keywords
    Attenuation measurement; Cables; Connectors; Dynamic range; Frequency measurement; IEC standards; Performance evaluation; Signal generators; Signal synthesis; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Conference, 1985. 15th European
  • Conference_Location
    Paris, France
  • Type

    conf

  • DOI
    10.1109/EUMA.1985.333590
  • Filename
    4132278