• DocumentCode
    2027799
  • Title

    Effect of rotor slots parameters on synchronization capability of slotted solid rotor line start permanent magnet motor

  • Author

    Niazazari, M. ; Mirsalim, Mojtaba ; Mohamadi, S.

  • Author_Institution
    Dept. of Electr. Eng., Amirkabir Univ. of Technol., Tehran, Iran
  • fYear
    2013
  • fDate
    13-14 Feb. 2013
  • Firstpage
    60
  • Lastpage
    65
  • Abstract
    Slotted solid rotor line-start permanent magnet motor has good synchronization capability in high load torque and high moment of inertia. This paper analysis the rotor slots parameters effect on the motor performance. These parameters are rotor slot length and width. For these, two important torques were considered. Starting torque and the torque near synchronization speed. For high synchronization capability these torques should be in high value. Result of sensitivity analysis shows, the rotor slot depth and width of 16.8 mm, and 2 mm, respectively was considered in case study motor design. At the end, a 4-pole, 1500 rpm, 750 watt, 3-phase line start synchronous motor with optimized slotted solid rotor is built.
  • Keywords
    permanent magnet motors; rotors; sensitivity analysis; synchronous motors; 3-phase synchronous motor; load torque; moment of inertia; power 750 W; rotor slot length; rotor slot width; sensitivity analysis; size 2 mm; slotted solid rotor line start permanent magnet motor; starting torque; synchronization capability; torque near synchronization speed; Magnetic analysis; Rotors; Stators; Synchronization; line start; rotor slots; slots length; slots width; synchronization capability;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics, Drive Systems and Technologies Conference (PEDSTC), 2013 4th
  • Conference_Location
    Tehran
  • Print_ISBN
    978-1-4673-4481-4
  • Electronic_ISBN
    978-1-4673-4483-8
  • Type

    conf

  • DOI
    10.1109/PEDSTC.2013.6506674
  • Filename
    6506674