DocumentCode
2036788
Title
Modified interferential method for locating coaxial cable faults
Author
Lopez-Lapena, O. ; López-Villega, J.M. ; Morante, J.R. ; Samitier, J.
Author_Institution
Dept. Fisica Aplicada i Electron., Enginyeria i Mater. Electron., Barcelona, Spain
Volume
2
fYear
1996
fDate
1996
Firstpage
822
Abstract
This paper presents an interferential method for locating coaxial cables faults which is insensitive to the reflections produced in the inner connector. The effect of the parasite reflections due to the variation of the cable geometry and the attenuation suffered by the wave emitted by the reflectometer are also analyzed
Keywords
circulators; coaxial cables; electromagnetic wave reflection; fault diagnosis; fault location; light reflection; radiowave interferometry; reflectometers; reflectometry; attenuation; cable geometry; coaxial cable faults; inner connector; interferential method; modified interferential method; parasite reflections; reflections; sinusoidal signals; Attenuation; Coaxial cables; Communication cables; Communication systems; Connectors; Distance measurement; Equations; Frequency; Geometry; Reflection;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation and Measurement Technology Conference, 1996. IMTC-96. Conference Proceedings. Quality Measurements: The Indispensable Bridge between Theory and Reality., IEEE
Conference_Location
Brussels
Print_ISBN
0-7803-3312-8
Type
conf
DOI
10.1109/IMTC.1996.507283
Filename
507283
Link To Document