DocumentCode
2057476
Title
Recent test results on the feasibility of a high coulombic thyratron
Author
Pirrie, C.A. ; Newton, B.P. ; Roberts, C.A.
Author_Institution
EEV Ltd., Chelmsford, UK
fYear
1995
fDate
34759
Firstpage
42491
Lastpage
42493
Abstract
The authors briefly discuss the requirements for HV switches used in capacitor bank discharges. The possible use of thyratrons for this purpose is discussed. It is pointed out that thyratrons have traditionally had is their inability to handle very long pulse widths at high peak currents. The authors then discuss the feasibility of such a high coulombic efficiency thyratron. The authors describe the test equipment and device development
Keywords
capacitor storage; pulsed power switches; thyratrons; HV switches; capacitor bank discharges; high coulombic thyratron; high peak currents; test equipment; very long pulse widths;