    Geometrical effects in the current measurement by Rogowski sensor

  • Author

    Kang, Seong-Hwa ; Park, Jeong-Nam ; Seong-Hwa Yang ; Lee, Yong-Shin ; Ham, Gil-Ho ; Yong-Mu Jang ; Lim, Kee-Joe

  • Author_Institution
    Dept of Electr. Eng, Chungbuk Nat. Univ., South Korea
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    419
  • Lastpage
    422
  • Abstract
    Rogowski coil is made having no ferromagnetic material in a core. So the coil cannot be driven into saturation. This result in that Rogowski coils may be calibrated at relatively low currents, and used with confidence at very high currents. However the lowest level of current that can be measured is limited by the sensitivity of the voltage measuring instrument and system noise. Therefore, geometrical effects were investigated in order to measure high sensitivity of low level current and the significant source of error was examined as well. In the results, the sources of error were associated with coil designs, i.e. shape, uniformity and a geometrical location of current source inside and outside of the Rogowski coil
  • Keywords
    coils; electric current measurement; electric sensing devices; measurement errors; Rogowski coil; Rogowski sensor; calibration; current measurement; current source; error source; geometrical effects; sensitivity; system noise; voltage measuring instrument; Coils; Conductors; Copper; Current measurement; Magnetic confinement; Magnetic field measurement; Magnetic materials; Noise measurement; Shape measurement; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulating Materials, 2001. (ISEIM 2001). Proceedings of 2001 International Symposium on
  • Conference_Location
    Himeji
  • Print_ISBN
    4-88686-053-2
  • Type

    conf

  • DOI
    10.1109/ISEIM.2001.973692
  • Filename
    973692