    High voltage cables that are used for DC transmission are subjected to a range of operating conditions. The resulting distribution of the electric field inside the cable is highly dependent on, for instance loading of the cable and polarity reversals. This is because the conductivity of the insulation is dependent both on the temperature and on the electric field. An essential parameter in the process to determine the internal electric field is space charge. For a thorough understanding of the behavior of the cable, knowledge of the location and amount of space charge under different operating conditions is paramount
  • Keywords
    HVDC power transmission; composite insulating materials; electric fields; power cable insulation; space charge; HVDC cable insulation; cable loading; electric field; operating conditions; polarity reversals; space charge; Cable insulation; Conductivity; Dielectrics and electrical insulation; HVDC transmission; Microscopy; Power cable insulation; Power cables; Space charge; Temperature dependence; Voltage;